DID642 - T-TECHNIK

DID642

. Catalog Air-water systems DID642

DID642

Wester_m 15.03.2024

DID642 SERIES

Active chilled beams for heating and cooling, with 2-pipe or 4-pipe heat exchanger, for integration into various ceiling systems

Recommended for rooms up to 4.0 m high
High heating and cooling capacity with low primary conditioned air flow and low noise level
Five nozzle options to optimize ejection levels depending on needs, including adjustable twin nozzles, i.e. pairs of nozzles of different diameters
Removable, folding recirculation grille in two versions

Additional equipment and accessories

Automation kit
Additional housing for supply and exhaust air, or additional supply air
Supply and extract air units on request
Adjustable guide lamellas to change the direction of air supply
Black powder coated heat exchanger
Powder coating in various colors, e.g. RAL CLASSIC scale
Also suitable for free hanging when fitted with an edge panel

Description

Active chilled beams supply conditioned primary (fresh) air to the room using heat exchangers to provide additional cooling and/or heating.

Primary air is supplied to the mixing chambers through nozzles (five options are possible). This allows secondary (room air) air to be drawn in through the recirculation grille and passed through a horizontal heat exchanger where it is heated or cooled.

Primary air is mixed with secondary air and supplied horizontally into the room through air outlet slots.

Nominal length 900, 1200, 1500, 1800, 2100, 2400, 2700, 3000 mm

Length 893 – 3000 mm

Height 170/205 mm

Width 593, 598, 618, 623 mm

Primary air pipe, diameter 123/158 mm

Primary air flow level 10 – 125 l/s or 36 – 450 m³/h

Cooling capacity Up to 3100 W

Heating capacity Up to 2330 W

Max. operating pressure, water circuit 6 bar

Max. working temperature 75°C

Characteristics

Adjustable guide lamellas to change the direction of air supply
Removable, folding recirculation grille in two versions
Horizontal heat exchanger for 2-pipe or 4-pipe system
Water connections at the end of the beam, copper tube Ø12 mm without thread or with external thread, or with G½” union nut, flat seal
Inner plate with stamped nozzles (non-flammable material)

Materials and coating

The body, recirculation grille, body panels at the end of the beam, pipes and mounting brackets are made of galvanized sheet steel
Sheet metal nozzle plate
Heat exchanger with copper pipes and aluminum fins
Guide slats made of polypropylene, fire resistance class V0 according to UL 94
External surfaces powder coated in white (RAL 9010) or other RAL CLASSIC colors
The heat exchanger is painted black (RAL 9005) 

① Hanging bracket
② Primary air pipe
③ Housing
④ Water connections
⑤ Heat exchanger
⑥ Nozzles (adjustable twin nozzles shown, on request)
⑦ Recirculation grille
⑧ Guide slats (on request)

Consultation / Order

Leave a request for consultation

Please enable JavaScript in your browser to complete this form.
Please enable JavaScript in your browser to complete this form.